PrevNext StopPlayPause  sec delay 
Return to Album
One more crack shot
This is the window next to the corner in the last 2 pictures. Again, note the astonishing number of cracks. Perhaps the cement in the stucco was mixed or applied wrong, or not given long enough to cure? Note that there are no expansion joints to allow for stucco movement, so some cracking was inevitable. There's no weep screed either - so no way for water to drain once it gets trapped back there.

On a happier note, the window at the bottom is level with the foundation and those vents are coming through the rim joist. Finally, a spot with proper grading. Let's hope this rim joist is in slightly better shape!
Panasonic DMC-FZ1 Full EXIF / IPTC
Photo 35 of 410, sm_CrackingUnderWindow.jpg, 40KB, 640x480, 87 Hits
Other Sizes: Medium Original
Properties | Link Back to Thumbnails