Installed a new ISO kit in auxillary hydraulic outlet to convert from old IH tips
Date(s): February 26, 2008. Album by Dan  Allred. 1 - 13 of 13 Total. 1775 Visits.
  Sign the Guestbook. There are no entries.
Start SlideshowTo order prints and photo-products: 1. Select photos. 2. Click Order. 3. Select products.Select images and click to download to your computer 
Enlarge photo 1
1
DSCF8010
Install new sealing rings in grooves. 2 sets per hole

Enlarge photo 2
2
DSCF8014
Notice the small pilot hole by the threaded hole

Enlarge photo 3
3
DSCF8015
Install coupler body into housing

Enlarge photo 4
4
DSCF8016
Install stepped washer with small OD toward body and tighten bolt

Enlarge photo 5
5
DSCF8017
Invert housing to install rubber boots

Enlarge photo 6
6
DSCF8018
Cut a groove in the bottom of boot for the oil to drain. Make sure you do it to the bottom

Enlarge photo 7
7
DSCF8019
I used a die grinder. It just takes a little bit

Enlarge photo 8
8
DSCF8020
Lubricate boot and install in housing

Enlarge photo 9
9
DSCF8021
Boot should go down flush to allow the snap ring grooves to align

Enlarge photo 10
10
DSCF8022
Installing other boot

Enlarge photo 11
11
DSCF8023
Install snap ring with the kit into grooves.

Enlarge photo 12
12
DSCF8024
More of the snap ring going in

Enlarge photo 13
13
DSCF8025
The finished outlet installed

 