Capillary moisture break will fold up on ICF wall on exterior and get counterflashed with exterior membrane. On the inside, it will tie onto the subslab vapor barrier for a continous sealed vapor retarder underslab.
"Rollie, I am an Badger transplanted to Georgia. Down here its poured foundation walls on the footers. Sometimes keyways done in the footer. Does the capillary moisture break still apply? We will be on a sloping lot." --Birdman, 10/19/05
"Capillary moisture breaks are not climate specific." --Rollie, 10/19/05